Impulse Relay Adjustable

The Im­pulse Relay Ad­justable is used when loads need to be switched on for a de­fined pe­riod of time and then switched off again with one input pulse. The out­put pulse length is user-ad­justable via po­ten­tiome­ter set­ting within five avail­able stan­dard time in­ter­vals. Cus­tom time in­ter­vals are avail­able on re­quest. Please spec­ify the de­sired stan­dard time in­ter­val in the pur­chase order.

 

Function

Di­a­gram S1: The sup­ply volt­age is con­nected to ter­mi­nal 30. When a volt­age sig­nal is ap­plied to ter­mi­nal 15 (trig­ger) the relay im­me­di­ately picks up for the spec­i­fied time pe­riod and drops out at the end of the time pe­riod cre­at­ing an out­put pulse of spec­i­fied length. The out­put pulse length is in­de­pen­dent of the volt­age sig­nal length ap­plied to ter­mi­nal 15 (sin­gle shot trig­ger).

Di­a­gram S2: The sup­ply volt­age is ap­plied to ter­mi­nal 87z. When a sig­nal volt­age is ap­plied to ter­mi­nal 15 the relay im­me­di­ately picks up for the spec­i­fied time pe­riod and drops out at the end of the time pe­riod. If the sig­nal volt­age on ter­mi­nal 15 is re­moved prior to the end of the spec­i­fied out­put pulse length the relay drops out im­me­di­ately. Out­put con­tacts are elec­tri­cally sep­a­rated from input con­tacts which al­lows for relay com­bi­na­tion so­lu­tions.

The de­sired out­put pulse length is user-ad­justable via po­ten­tiome­ter set­ting. Please refer to the chap­ter hous­ing and base plates for ad­di­tional hous­ing op­tions.

Application Examples

Application Examples
En­gine pre­heat

Technical data

Product Name Value
Op­er­at­ing tem­per­a­ture -40 °C to 85 °C
Out­put pulse length See time in­ter­valls
Con­tin­u­ous cur­rent limit 10A/15 A (no/nc)
Pulse time ac­cu­racy +/- 1 %
En­vi­ron­men­tal pro­tec­tion IP53 (with po­ten­tiome­ter cover)
Qui­es­cent cur­rent 250 µA
e1 ap­proval num­ber 03 3218

Function Diagram

Design

Connection diagram

Product Details

Product Name Model Housing Order No.
Im­pulse relay ad­just. 12V A S1/G2/E 1.​022.​115.​XXE
Im­pulse relay ad­just. 24V A S1/G2/E 1.​022.​215.​XXE
Im­pulse relay ad­just. 12V C S2/G2/E 1.​022.​114.​XXE
Im­pulse relay ad­just. 24V C S2/G2/E 1.​022.​214.​XXE

Accessories

Product Name Order No.
Pro­gram­ming tool MRS Re­al­izer I 1.​100.​000.​01
Flat pin socket 1.​017.​002.​00
FAS­TON ter­mi­nal 6.3 mm 1.5-2.5 mm2 103064
FAS­TON ter­mi­nal 6.3 mm 1 mm2 102355
FAS­TON ter­mi­nal 2.8mm 0.5-1.0 mm2 105292
Bracket for hous­ing 1.​017.​080.​00

Function Table

Standard Interval optionsOutput pulse range
XX = 01:0.5 - 5 sec.
XX = 02:1 - 30 sec.
XX = 03:0.5 - 60 sec.
XX = 04:30 - 900 sec.
XX = 05:0.5 - 4000 sec.